Applications

 

Series 707L

Relay 707L designed to meet the in-rush requirements for lamp loads

 

Electrical Life for the Various Lamp Loads 100,000 cycles 30,000 cycles
Incandescent lamp 1250 W 2500 W
Fluorescent lamp, not compensated 1200 W 2500 W
Fluorescent lamp, parallel compensated 650 W / 70 m F 1300 W / 140 m F
Fluorescent lamp, dual-circuit 2 x 1200 W 2 x 2500 W
Halogen lamp (230Vac) 1200 W 2500 W
Low voltage halogen lamp with transformer 500 VA 500 VA
Mercury lamp, not compensated 1000 W 2000 W
Mercury lamp, parallel compensated 1000 W / 70 m F 2000 W / 140 m F
Mercury lamp, parallel compensated 1000 W / 70 m F 2000 W / 140 m F
Dulux lamp, not compensated 800 W 1600 W
Dulux lamp, parallel compensated 560 W / 70 m F 1100 W / 140 m F
Series 704

Relay 704 designed to meet the in-rush requirements for lamp loads

Electrical Life for the Various Lamp Loads 30,000 cycles
Incandescent lamp 4800 W
Fluorescent lamp, not compensated 5000 W
Fluorescent lamp, parallel compensated 2500 W / 200 m F
Fluorescent lamp, dual-circuit 2 x 2500 W
Halogen lamp (230Vac) 500 W
Low voltage halogen lamp with transformer 2000 VA
Mercury lamp, not compensated 5000 W
Mercury lamp, parallel compensated 5000 W / 200 m F
Dulux lamp, not compensated 4000 W
Dulux lamp, parallel compensated 3000 W / 200 m F
Series 730
Relay 730 will be available in the first quarter of 1999. Model 730 is available in DPST or 3PST at 60 A or 100 A. The relay meets the requirements of 3-phase meters.
Series 740

 

Relay 740 was designed for the utility market to allow remote disconnect / reconnect. The AMR communication sends a signal to relay 740, which in turn disconnects / reconnects the household. The relay is available in two versions, different only in the contact terminal configuration. The 740A model was designed to fit inside the meter under the glass. The 740B interbase version fits in an extender base, the electric meter plugs in on top. Extender bases are available from EKSTROM as well as from MARWELL.